APC PDUs - Rack Mounted - Refurbished, Used and New
APC rack PDUs distribute power from a single rack feed to the servers, switches and storage in a cabinet, and the Metered and Switched models report load and let you turn individual outlets on and off over the network. This collection covers the AP7xxx and AP8xxx rack PDU families and the newer Rack PDU 9000 series in Basic, Metered, Switched and Metered-by-Outlet versions, in 1U and 2U horizontal and Zero U vertical form factors, for 120V, 208 to 240V and 3-phase feeds. It also includes APC rack automatic transfer switches, which keep single-corded equipment running by switching between two power sources. NetworkTigers sells APC rack PDUs and transfer switches refurbished, used and new, and every unit is tested before it ships.
APC rack PDU types and models
| Type and input | Used for | Shop |
|---|---|---|
| Switched 1U, 120V | 8x NEMA 5-15R or 5-20R outlets, 15A or 20A; remote outlet control for a small rack or network closet | AP7900 | AP7901 | AP7900B |
| Metered 1U, 120V | 8x NEMA 5-15R outlets, 20A; load reporting without outlet switching | AP7801 |
| Switched Zero U, 120V | 24x NEMA 5-20R outlets, 20A or 30A, vertical mount for full racks | AP7930 | AP7932 | AP8930 | AP8932 |
| Metered Zero U, 120V | 24x NEMA 5-20R outlets, 30A, load reporting only | AP8832 |
| Switched 1U, 208 to 230V | 8x IEC C13 outlets for a few servers on a 208V feed | AP7920 | AP7921 | AP7922 |
| Metered 1U and 2U, 208 to 230V | 8x C13 at 16A, or 12x C13 and 4x C19 at 30A for blade chassis and larger loads | AP7821 | AP7821B | AP7811 | AP7811B |
| Switched 2U, 208V 30A | 16x C13 outlets in a horizontal chassis | AP7911A | AP7911B |
| Switched Zero U, 208 to 240V | 21x C13 and 3x C19 outlets at 20A, 30A or 32A; the most common data center rack PDU | AP8941 | AP7940 | AP8959 | AP8959NA3 | AP8953 | AP8958 |
| Metered Zero U, 208 to 240V | C13 and C19 outlets at 20A or 30A, load reporting without switching | AP8641 | AP8858NA3 | AP8661 |
| 3-phase 208V, Zero U | Switched or Metered, 30x to 36x C13 plus C19 outlets, 20A to 60A per phase, for dense racks | AP8865 | AP8868 | AP8867 | AP7961 | AP7991 | AP7894 | AP7893 |
| Rack PDU 9000 series | Current-generation Switched Zero U units with a color display and C13 and C19 outlets | APDU9965 | APDU9959NA3 |
| Rack automatic transfer switches | Two power inputs, one set of outlets; keeps single-corded gear up when one feed fails | AP7721 | AP7750A | AP7730 | AP7732 | AP7752 | AP4423 | AP4432 |
| Management cards and cables | UPS network management card with environmental monitoring, and the DB9 to RJ12 console cable | AP9631 | 940-0144A |
| Related APC | Browse by input voltage, phase or device type | 120V 15A | 120V 20A | 120V 30A | 208-240V | 3-phase | Rack ATS | APC Symmetra UPS |
Which APC PDU do I need?
Start with the feed: the input voltage, amperage and receptacle on the rack circuit decide the PDU, and the outlets follow from the voltage. A 120V circuit gives you NEMA outlets: 5-15R and 5-20R are the familiar three-prong receptacles, and the PDU plugs in with a straight 5-15P or 5-20P or, for a 30A circuit, a twist-lock L5-30P. A 208V or 230V circuit gives you IEC outlets: C13 outlets accept the C14 cord on nearly every server and switch, and the larger C19 outlets accept the C20 cord on blade chassis, big storage arrays and high-wattage power supplies; the PDU input is usually a twist-lock L6-20P or L6-30P. Then count outlets with 20 percent spare, add up the load so it stays under 80 percent of the circuit rating, and pick Metered if you only need load readings and Switched if you want to reboot a hung server remotely or lock unused outlets off.
Frequently asked questions
Can I use a 208V PDU on a 120V circuit?
No. The input plug, the outlet type and the internal metering are built for one voltage range. Match the PDU to the circuit and receptacle you have, or have an electrician change the circuit first.
Do I need a separate network card to manage a Switched PDU?
No. Metered and Switched rack PDUs have the network management interface built in, with an RJ45 port and a serial console port. Each unit is reset to factory defaults before it ships. The AP9631 card on this page is for an APC UPS, not for a PDU.
How is a Metered-by-Outlet PDU different from a Metered one?
A Metered PDU reports the total load on the unit or per bank. A Metered-by-Outlet PDU reports current and energy for every outlet, which lets you charge back power by server or find the one drawing more than it should.
NetworkTigers has sold enterprise network equipment since 1996. Every PDU and transfer switch carries the NetworkTigers 365-day warranty. Need a quantity or a specific outlet layout? Ask us for a quote.
APC AP8941 Switched 200-208V 30A 21x IEC-320-C13 3x IEC-320-C19 Zero U PDU
APC AP7940 Switched Rack 200-208V 20A 3x C19 21x C13 Zero U PDU
APC AP7901 Switched Rack 120V 20A 8x NEMA 5-20R 1U PDU
$ 187.99
$ 206.99
Call if you need more
APC AP7811 Metered 12x IEC 320 C13 4x C19 30A 208V 2U Rack Mounted PDU
APC SYMIM5 Symmetra LX Intelligence Power Control Module
$ 799.99
$ 1,175.99
Call if you need more
APC AP8959NA3 Switched Rack 200V-240V 20A 21x C13 3x C19 ZeroU PDU
APC AP7721 12x C13, 208V or 230V Automatic Transfer Switch
APC AP7900 Switched Rack 120V 15A 8x NEMA 5-15R 1U PDU
APC AP9631 2 x Environmental Monitoring 1 x RJ45 10/100 UPS Management Card
$ 245.99
Call if you need more
APC AP8865 Metered 3 PH 30A 2G 8.6kW 208V 36x C13 6x C19 2x 5-20 ZeroU Rack PDU
APC AP7750A 120V 15A 8x NEMA 5-15R Rack Mount Automatic Transfer Switch
APC AP7911A Switched 16x IEC 60320 C13 Rack Mount 208V 30A PDU
APC AP8832 Metered Rack 120V 30A 24x NEMA 5-20R Zero U PDU
APC AP7921 Switched Rack 200V,208V,230V 20A 8x IEC 60320 C13 1U PDU
APC AP8641 Metered Rack 200-208V 30A 21x IEC 60320 C13 3x C19 Zero U PDU
APC AP8858NA3 Metered Rack 200-208V 20A 18x C13 2x C19 ZeroU PDU
NEW APC 940-0144A Serial Console Cable DB9 to RJ12
$ 31.99
Call if you need more